IRC R507 · Decks · 2021 / 2024 IRC
Joists, beams, ledger fastening, posts, and footings — the order to size a prescriptive deck and where each answer lives. Free links to the IRC and the AWC DCA 6 deck guide.
Need the actual tables? Read IRC R507 free at codes.iccsafe.org → or get the free AWC DCA 6 deck guide →
| Step | Part | What sets it | Where to look |
|---|---|---|---|
| 1 | Decking | Decking type and joist spacing (and angle of the boards) | IRC R507 decking section / DCA 6 decking rules |
| 2 | Joists and cantilever | Species, size, spacing, and the joist span you want | IRC R507 deck joist table / DCA 6 joist table |
| 3 | Beams | Beam size and ply count, plus the joist span it supports | IRC R507 deck beam table / DCA 6 beam table |
| 4 | Posts | Post size and height | IRC R507 post table / DCA 6 post table |
| 5 | Footings | Tributary area of each post and the soil bearing value | IRC R507 footing table / DCA 6 footing table + local frost depth |
| 6 | Ledger to house | Joist span (tributary load on the ledger) and what the ledger attaches to | IRC R507 ledger fastener table / DCA 6 ledger table |
| 7 | Lateral connection | Hold-down devices tying the deck to the house floor framing | IRC R507 lateral load connection / DCA 6 |
| 8 | Guards and stairs | Deck height above grade, stair geometry | IRC R311/R312 / DCA 6 |
Section and table numbers inside R507 have moved between editions — search by topic in your adopted edition. Our own summary, not the code text. Read IRC R507 free at codes.iccsafe.org or the free AWC DCA 6 guide, and verify against the IRC edition and local amendments adopted by your AHJ. Not engineering advice.
| Input / step | Value | Source |
|---|---|---|
| Design loads the prescriptive tables assume | 40 psf live, 10 psf dead | DCA 6 / IRC R507 |
| Joist span wanted (ledger face to beam face) | 11 ft 0 in | Layout |
| Joist choice | Southern pine No. 2, 2x8 at 16 in o.c. | Lumber on hand |
| Maximum joist span from the table | 11 ft 10 in | AWC DCA 6 (2015), joist table |
| Result | Works — 11 ft 0 in is less than 11 ft 10 in | Compare |
| Ledger fasteners | 1/2 in lag screws or through-bolts with washers, spaced per the ledger table for an 11 ft joist span | DCA 6 / IRC ledger fastener table |
| Posts | 6x6 minimum | DCA 6 post requirements |
| Footings | Bottom at least 12 in below undisturbed ground or below the frost line, whichever is deeper | DCA 6 / IRC R403.1.4 |
Worked example values only. Look up the full tables in the free AWC DCA 6 guide or the IRC at codes.iccsafe.org.
| Mistake | What to do instead |
|---|---|
| Nailing the ledger to the band joist | Use the lag screws or bolts in the ledger table — nails alone are not a ledger connection |
| Lagging into brick veneer, or using lead anchors in masonry | Veneer can’t carry a ledger — go free-standing (non-ledger deck) or attach to the structure behind it |
| Skipping ledger flashing | Flash the ledger so water stays off the house band joist |
| Bolting the beam to the side of the post | Notch the post or use a post cap so the beam bears on the post |
| Setting a deck footing next to the house above the house footing | Deck footings close to the house bear at the house footing elevation (see DCA 6) |
| Measuring joist span to the end of the cantilever | Span is face of support to face of support; the overhang is checked separately |
Our own summary, not the code text. Read IRC R507 free at codes.iccsafe.org or the free AWC DCA 6 guide, and verify against the IRC edition and local amendments adopted by your AHJ. Not engineering advice.
Paste this where you want the live chart to appear. It works on any site that allows iframes, and includes a link back to Field PM.
<iframe src="https://www.field-pm.com/embed/charts/irc-deck-framing-requirements" title="IRC Deck Framing (R507) Explained — Field PM" width="100%" height="620" loading="lazy" style="border:1px solid #e5e7eb;border-radius:12px;max-width:560px;width:100%"></iframe> <p style="font:13px/1.5 system-ui,sans-serif;margin:8px 0;color:#6b7280"><a href="https://www.field-pm.com/charts/irc-deck-framing-requirements" target="_blank" rel="noopener">IRC Deck Framing (R507) Explained</a> by <a href="https://www.field-pm.com" target="_blank" rel="noopener">Field PM</a></p>
Two free sources: read IRC R507 free at codes.iccsafe.org, and download the American Wood Council’s DCA 6 Prescriptive Residential Wood Deck Construction Guide. This page explains how to use them; it does not reproduce their tables. It covers the 2021 and 2024 IRC — verify against the edition your AHJ adopted.
Work from the top down. Decking sets the joist spacing. Joist span and spacing set the joist size and how far it can cantilever. The joist span sets what each beam carries, which sets the beam size and post spacing. The area each post supports sets the footing size. And the joist span sets how many ledger bolts you need at the house. Change the layout and you rerun the chain.
The ledger is where decks fail. The prescriptive rules only work when the ledger bolts or lags through into a solid band or rim joist, with flashing. Brick veneer, cantilevered floors, and I-joist rims without blocking are outside the tables — go free-standing on its own beam, or get it designed.
Worked example. A ledger-attached deck needs 11 ft joists. Southern pine No. 2 2x8 at 16 in o.c. is listed at 11 ft 10 in in DCA 6 (40 psf live, 10 psf dead), so it works. The ledger gets 1/2 in lag screws or bolts at the spacing the ledger table gives for an 11 ft span, posts are 6x6 minimum, and the footings go below the frost line and at least 12 in below undisturbed ground.
Related: how to read IRC span tables, IRC footing sizes, and frost depth and design criteria (R301.2). Estimate footing concrete with the concrete calculator, and log the footing and final inspections in the inspection request log.
DCA 6 is the American Wood Council’s Prescriptive Residential Wood Deck Construction Guide. It is free to download from awc.org, follows the IRC deck provisions, and adds illustrated details for ledgers, posts, beams, guards, and stairs. Many building departments hand it out as the deck standard.
It depends on species, spacing, and cantilever. As one example, DCA 6 (2015) lists 11 ft 10 in for southern pine No. 2 at 16 in on center with 40 psf live and 10 psf dead load. Look up your exact case in DCA 6 or IRC R507.
Through the house band or rim joist with 1/2 in lag screws or through-bolts with washers, spaced per the ledger fastener table for your joist span, with flashing to keep water off the band. The prescriptive tables don’t cover attaching to brick veneer or cantilevered floors — use a free-standing deck or a design.
At least 12 in below undisturbed ground or below the frost line your jurisdiction lists in Table R301.2, whichever is deeper. Footing size comes from the deck footing table based on the area each post supports and the soil bearing value.
The IRC includes a prescriptive lateral load connection — hold-down devices tying the deck joists to the house floor framing — or an approved design. Check the lateral provisions in the R507 edition your AHJ adopted.