IECC R402 / C402 · ASHRAE 90.1 envelope
Climate zones, cavity vs continuous insulation, window U-factors, and prescriptive vs performance compliance — how the energy code envelope tables work, with a worked example and a link to the free ICC viewer.
Need the actual tables? Read IECC Chapter 4 in the free ICC code viewer →
| Step | What you do | Watch out for |
|---|---|---|
| 1 | Find the climate zone for the county (IECC Chapter 3 table/map) | A number (thermal) plus a letter (A moist, B dry, C marine); some tables split on the letter or on "marine 4" |
| 2 | Decide residential vs commercial: R-chapter for low-rise dwellings, C-chapter (or ASHRAE 90.1) for everything else | Apartments over three stories fall under the commercial provisions |
| 3 | Pick the compliance path: prescriptive R-value table, U-factor/UA alternative, or performance | Mixing paths component by component isn’t allowed unless the path permits trade-offs |
| 4 | Find the component row (ceiling, wood-frame wall, mass wall, floor, slab, basement wall) and read the climate-zone column | Commercial tables also split by construction type (metal building, steel-framed, mass) and by roof type |
| 5 | Read the notation: first number is cavity, "ci" is continuous insulation | "20+5ci" means R-20 in the cavity plus R-5 continuous — not R-25 anywhere you like |
| 6 | Read fenestration separately: maximum U-factor (lower is better) and SHGC where it applies | U-factor is the whole NFRC-rated unit, not the glass center |
| 7 | Read the table footnotes | Footnotes carry the exceptions (e.g., reduced attic R-value at raised-heel eaves, log walls, slab depth) |
Our own summary, not the code text. Read IECC Chapter 4 (residential and commercial) in the free ICC viewer (codes.iccsafe.org); ASHRAE 90.1 is published by ASHRAE. Verify against the energy code edition — and any state amendments — adopted by your AHJ.
| Path | How it works | When contractors use it |
|---|---|---|
| Prescriptive R-value | Meet or beat every component R-value in the table | Simple jobs; the inspector checks labels and cert cards |
| U-factor alternative | Meet the assembly U-factor for each component | Nonstandard assemblies (SIPs, advanced framing, mass walls) |
| Total UA trade-off (REScheck / COMcheck) | The whole envelope’s area-weighted UA must not exceed the code-reference house/building | Trading more glass for better walls or attic |
| Performance (R405 / C407) or ERI (R406) | Energy model shows proposed design uses no more energy than the standard reference | Unusual designs; mandatory provisions still apply |
| ASHRAE 90.1 (commercial alternative) | Section 5 prescriptive tables by climate zone, or trade-off/modeling methods | Owners or engineers who design to 90.1 instead of IECC C-chapter |
Our own summary, not the code text. Read IECC Chapter 4 (residential and commercial) in the free ICC viewer (codes.iccsafe.org); ASHRAE 90.1 is published by ASHRAE. Verify against the energy code edition — and any state amendments — adopted by your AHJ.
| Input / step | Value | Source |
|---|---|---|
| County lookup | Climate zone 5A | IECC climate zone table |
| Path chosen | Prescriptive R-value | Builder choice |
| Ceiling / attic insulation | R-60 | R-value table, ceiling row, zone 5 |
| Windows (whole-unit NFRC label) | U-0.30 or lower | Fenestration U-factor, zone 5 |
| Submitted window: U-0.28 | Passes (0.28 ≤ 0.30) | Lower U-factor is better |
| Attic with full-height R-49 over the top plate at the eaves | May satisfy the R-60 row | Table footnote exception |
Worked example values only (2021 IECC). Look up the full tables in the ICC viewer and check state amendments.
| Mistake | What to do instead |
|---|---|
| Reading a higher U-factor as better | U-factor is heat flow — lower is better; R-value is resistance — higher is better |
| Adding cavity and ci together and installing all of it in the cavity | Continuous insulation must be continuous across framing to count as "ci" |
| Using the county from the job name instead of the site | Check the county the building sits in; a few counties straddle a zone line in newer editions |
| Assuming the model code is what’s enforced | Many states amend the IECC or stay on an older edition — energycodes.gov tracks adoption |
| Compressing batts at the eaves | Use raised-heel trusses or baffles so the full depth reaches the wall line |
Our own summary, not the code text. Read IECC Chapter 4 (residential and commercial) in the free ICC viewer (codes.iccsafe.org); ASHRAE 90.1 is published by ASHRAE. Verify against the energy code edition — and any state amendments — adopted by your AHJ.
Paste this where you want the live chart to appear. It works on any site that allows iframes, and includes a link back to Field PM.
<iframe src="https://www.field-pm.com/embed/charts/insulation-r-values-iecc-climate-zones" title="IECC Insulation R-Values & Climate Zones — Field PM" width="100%" height="620" loading="lazy" style="border:1px solid #e5e7eb;border-radius:12px;max-width:560px;width:100%"></iframe> <p style="font:13px/1.5 system-ui,sans-serif;margin:8px 0;color:#6b7280"><a href="https://www.field-pm.com/charts/insulation-r-values-iecc-climate-zones" target="_blank" rel="noopener">IECC Insulation R-Values & Climate Zones</a> by <a href="https://www.field-pm.com" target="_blank" rel="noopener">Field PM</a></p>
Read the tables in the free ICC code viewer. IECC Chapter 4 holds the residential (R402) and commercial (C402) envelope tables. ASHRAE 90.1 Section 5 is the commercial alternative, sold by ASHRAE. This page explains how to use them; it does not reproduce them. Edition referenced: 2021 IECC, with notes on 2018 and 2024 — verify against the edition adopted by your AHJ, and check energycodes.gov for state adoption status.
Climate zone first. Every envelope number hangs on the zone: a thermal number (0 hottest to 8 coldest) and a moisture letter (A moist, B dry, C marine). Zones come from a county table, not your gut — two jobs an hour apart can land in different zones. The residential tables mostly key off the number; commercial tables also split by construction type, so a metal building and a wood-framed building in the same zone read different rows.
R-values vs U-factors. The R-value table lists minimum insulation you install, written as cavity plus continuous ("ci"). The U-factor table lists maximum heat flow for the whole assembly, which lets engineered assemblies comply even if they don’t look like the R-value row. Fenestration is always a U-factor — lower is better — and in warmer zones an SHGC limit applies too.
Worked example. A new house in zone 5A under the 2021 IECC prescriptive path: the ceiling row calls for R-60 and the fenestration column for U-0.30 or lower. A window labeled U-0.28 passes. A footnote lets full-depth R-49 that extends over the wall top plate at the eaves stand in for R-60, which is why raised-heel trusses matter. If the builder wants more glass than the prescriptive path tolerates, REScheck’s UA trade-off or the performance path is the way out — not skipping insulation.
Related references: the duct construction and Manual J/S/D guide (loads depend on this envelope) and the IBC fire-resistance ratings guide (foam plastic and exterior-wall assemblies carry fire rules too). Field PM keeps insulation certificates, photos before cover, and inspection results with the job so the energy inspection has its paperwork.
Look up the county in the climate zone table in IECC Chapter 3 (residential R301 or commercial C301). The zone is a number from 0 to 8 plus a moisture letter: A (moist), B (dry), or C (marine). Read it free in the ICC viewer at codes.iccsafe.org.
It means R-20 of cavity insulation between the studs plus R-5 of continuous insulation installed across the framing, usually as foam or mineral-wool board on the exterior. The continuous layer cuts thermal bridging through the studs.
Yes. U-factor measures how much heat flows through the window, so lower numbers mean better performance. Under the 2021 IECC in climate zone 5, residential windows must be U-0.30 or lower under the prescriptive path — check your adopted edition.
The 2021 edition raised the prescriptive ceiling requirement in the colder zones — zone 5 went to R-60 from the R-49 in the 2018 edition — with a footnote that lets full-depth R-49 over the top plate satisfy it. The 2021 edition also added climate zone 0, which doesn’t occur in the U.S.
No. You can also comply with the U-factor alternative, a total UA trade-off (REScheck or COMcheck), or the performance path with an energy model. Mandatory provisions such as air sealing and duct testing apply on every path.