Free backflow test form · Excel

Free Backflow Test Report Template

Field test report for RP, DC, PVB, SVB and detector assemblies — readings graded against your purveyor's minimums, repairs, tester and gauge status, next-due date — plus an assembly register that flags overdue retests.

  • RP, DC, PVB, SVB, RPDA and DCDA assemblies
  • Check valve, relief valve and air inlet readings (psid)
  • PASS / FAIL against minimums you enter from your program
  • Initial and after-repair tests + repairs / parts table
  • Tester cert and test-kit calibration status on test date
  • Next test due calculated from your retest interval
  • Assembly register with OVERDUE / DUE SOON flags

Backflow Test Report

We'll email you a copy + send the file to your browser right now.

Excel (.xlsx) · works in Excel, Google Sheets, Numbers

Want it with your logo on it?

A free account puts your logo, company info, and license # on every template, and adds one-click template packs. Free forever, even after the trial.

Get branded templates free →

By downloading you agree to receive occasional Field PM updates. Unsubscribe anytime. We don't share your email — read our privacy policy.

What's inside the workbook

Pre-formatted, print-ready, with embedded Field PM branding. Works in Excel, Google Sheets, and Numbers.

01

Backflow Test Report

One assembly per report: customer, purveyor, assembly details, readings with PASS/FAIL, repairs, tester certification, gauge calibration, next test due and signatures.

02

Assembly Register

Every assembly on a site or route with last test, result, interval, next due, days to due and a CURRENT / DUE SOON / OVERDUE / FAILED status.

03

Instructions

Where the acceptance criteria come from, how to record each reading, and how to run the register.

Want this automated?

Stop re-typing the same form on every job.

Field PM has this exact form built in — crews fill it out from a phone, the data flows into the project record, and you get a clean PDF for the GC or owner with one click. No re-typing, no lost paperwork, no missed signatures.

30 days free · no credit card · every feature unlocked from day one.

Paper / Excel

  • ✗ Hand-writes the form on the jobsite
  • ✗ Re-types into Excel at the trailer
  • ✗ Emails the PDF back to the office
  • ✗ No audit trail, no signatures
  • ✗ Data never feeds payroll or the budget

Field PM

  • ✓ Fill out from a phone in under 3 min
  • ✓ Photos, signatures, and audit log built in
  • ✓ One-click PDF for the GC and owner
  • ✓ Data feeds payroll, budget, and reports
  • ✓ Replaces 5 forms with one platform

On your phone & tablet

Every template — in the app, in your pocket

This template and every other one is built into the Field PM app. Fill them out right from the jobsite on any iPhone, iPad, or Android — photos, signatures, and a clean GC-ready PDF included. Download free:

Download on theApp StoreGet it onGoogle Play

Frequently asked questions

What goes on a backflow test report?

The customer and water purveyor, the assembly (type, make, model, size, serial number, specific location, hazard and service), the test readings — check valve differentials, closed-tight results, relief valve opening point or air inlet opening — the result, any repairs and parts, the tester's certification number, the test kit and its calibration date, and the test date. Most purveyors also want the date the report was submitted.

Does the template include pass/fail values?

No. Minimum acceptable readings come from your water purveyor or state program and the field test procedure you are certified to — most commonly the USC Foundation for Cross-Connection Control and Hydraulic Research (FCCCHR) Manual of Cross-Connection Control. You enter those minimums once in the Criteria column and every reading shows PASS or FAIL against them; until you do, lines read "SET MIN".

Which assembly types does it cover?

Reduced pressure principle (RP), double check valve (DC), pressure vacuum breaker (PVB), spill-resistant vacuum breaker (SVB), and the detector versions used on fire lines (RPDA, DCDA). Each reading line shows which types it applies to.

How often do backflow assemblies have to be tested?

Most purveyors require testing at installation, annually, and after any repair or relocation; some require more frequent testing on high-hazard or specific assemblies. The report calculates the next due date from the test date and a retest interval you set (12 months by default), and the register flags every assembly that is due soon or overdue.

Can I submit this form to my water purveyor?

Many purveyors require their own form or an online portal. Use this workbook as your field record and company file, transfer the values to the purveyor's form or portal, and record the submittal date and confirmation number on the report.

Test it, grade it, and never miss a retest

A backflow preventer test report documents the annual — or after-repair — field test of a backflow prevention assembly: the assembly, its readings, the result, repairs, and the certified tester and calibrated test kit that produced them. Water purveyors require it for every testable assembly on their system.

This free Excel template gives certified testers and plumbing service contractors a test report that grades each reading against the minimums you enter from your program — commonly the USC FCCCHR field test procedures — and an assembly register that calculates next-due dates and flags overdue assemblies. Pair it with the plumbing pressure test report for new installs.

Field PM's service and dispatch module turns the register into scheduled recurring work orders, with the report, photos and invoice on the tech's phone.

A backflow test report is a public-health record

A backflow prevention assembly is the only thing standing between a building's plumbing — boiler chemicals, irrigation fertilizer, fire-line water that's been sitting for years — and the public water supply. That's why water purveyors require certified testers, calibrated test kits, annual retests and a written report for every assembly. The report is what the purveyor audits, what the owner's insurer asks for, and what protects the tester if something goes wrong downstream later.

The free template above gives backflow testers and plumbing service contractors a clean field test report for a single assembly and a register to keep an entire route or campus on schedule.

What's in the workbook

1. Backflow Test Report

Customer and purveyor details; the assembly — type (RP, DC, PVB, SVB, RPDA, DCDA), size, serial, make/model, a location specific enough to find it again, hazard, service and test type; an acceptance-criteria column you fill in from your program; initial and after-repair readings with a PASS / FAIL on every line and an overall result; a repairs and parts table; tester certification and expiration; test kit and calibration status; and the next test due date.

2. Assembly Register

Forty rows for every assembly at a site or on your route: ID, site, location, type, hazard, size, make, model, serial, service, last test date and result, tester, retest interval, next due, days to due and a STATUS column — CURRENT, DUE SOON, OVERDUE, or FAILED — REPAIR. A "sent to purveyor" column turns amber when a test was recorded but the report hasn't gone in.

Why you enter the acceptance criteria

Pass/fail minimums for check valves, relief valves and air inlets are set by the test procedure your program uses. The most common method in the US is the field test procedure in the USC FCCCHR Manual of Cross-Connection Control; some states and purveyors follow ABPA, AWWA M14 or their own procedure. Because the criteria belong to those programs — and can differ — this workbook doesn't reproduce them. Enter the minimums your program requires once, save the file as your company master, and every report you start from it grades itself.

How to fill out the test report

SectionWhat to record
AssemblyType, size and serial exactly as on the data plate. The serial number is how the purveyor matches your report to their record — a typo creates a "missing test" letter.
LocationRoom, equipment, height, upstream/downstream reference. "Mech room" isn't enough on a campus with six mechanical rooms.
Hazard / ServiceHealth (high hazard) vs. non-health, and containment vs. isolation. It determines which assembly types are acceptable and sometimes the retest interval.
ReadingsOnly the lines that apply to the assembly type. Differentials in psid; closed-tight and opened lines as Yes / No.
RepairsParts cleaned or replaced for each component, then the after-repair readings. The assembly status uses the final result if there is one.
Tester & test kitCert number and expiration, test kit serial and calibration date. The sheet flags an expired cert or gauge on the test date.
Next test dueCalculated from the test date and the retest interval.

Field notes from the test route

  • Coordinate before you shut a fire line. Closing the shutoffs on a DCDA or RPDA takes the sprinkler system out of service. Notify the owner and the monitoring company and follow the fire impairment procedure first.
  • Warn the occupants. Testing interrupts water. Hospitals, labs and restaurants need notice.
  • Flush the test cocks. Debris in the test cocks throws off readings and damages the kit.
  • A dripping relief valve is a symptom. Constant discharge on an RP usually points at the #1 check fouling or pressure fluctuation upstream. Note it even if the assembly passes.
  • Winterize after testing. Irrigation PVBs tested in the fall freeze quickly if you leave them charged.
  • Submit on time. Many purveyors require results within a set number of days. The register's amber "sent" flag catches the reports that are sitting in the truck.

When to move beyond Excel

A backflow testing business lives on recurring work: hundreds of assemblies, each due on its own date, each needing a report, a purveyor submittal and an invoice. Field PM's service and dispatch module schedules recurring tests, puts the report on the tech's phone with photos and signatures, and invoices the customer when the job closes. Start a free 30-day trial — no credit card required.

Related templates

Rated by contractors on

Field PM reviews on CapterraField PM reviews on GetAppField PM reviews on Software Advice